# 🌱 Auto Garden
|
||
|
||
> Automated garden monitoring and control system using Raspberry Pi Pico W
|
||
|
||
## Overview
|
||
|
||
This project automates garden monitoring using a Raspberry Pi Pico W with temperature sensors, Discord notifications, and AC control for climate management.
|
||
|
||
## Features
|
||
|
||
- ✅ WiFi connectivity with auto-reconnect
|
||
- ✅ Inside/Outside temperature monitoring (DS18B20 sensors)
|
||
- ✅ Discord notifications for temperature readings
|
||
- ✅ Separate alert channel for critical temperatures
|
||
- ✅ Temperature logging to CSV file
|
||
- ✅ Configurable alert thresholds
|
||
- ✅ Automated AC control with temperature swing logic
|
||
- ✅ Relay control via opto-coupler for 110V AC
|
||
- 🚧 Humidity monitoring (planned)
|
||
- 🚧 Soil moisture monitoring (planned)
|
||
- 🚧 Additional relay control for fans, heaters (planned)
|
||
|
||
## Quick Start
|
||
|
||
### 1. Hardware Setup
|
||
|
||
**Required Components:**
|
||
|
||
- Raspberry Pi Pico W
|
||
- DS18B20 temperature sensors (waterproof recommended)
|
||
- 4.7kΩ resistor (pull-up for 1-Wire bus)
|
||
- Opto-coupler relay module (3.3V logic, 110V AC rated)
|
||
- Momentary button (optional, for easy reset)
|
||
|
||
See the [Items Needed Wiki](https://gitea.rcs1.top/sickprodigy/Auto-Garden/wiki/Items-Needed-for-the-Project) for full parts list.
|
||
|
||
### 2. Wiring
|
||
|
||
**DS18B20 Temperature Sensors:**
|
||
|
||
```text
|
||
Sensor Wire → Pico Pin
|
||
─────────────────────────────
|
||
Red (VDD) → 3V3 (OUT) - Pin 36
|
||
Black (GND) → GND - Any ground pin
|
||
Yellow (Data) → GP10 (Inside) - Pin 14
|
||
→ GP11 (Outside) - Pin 15
|
||
|
||
Add 4.7kΩ resistor between Data line and 3.3V
|
||
```
|
||
|
||
**⚠️ Important:** The 4.7kΩ pull-up resistor is **required** for reliable 1-Wire communication. While it may work without it occasionally, you'll experience intermittent failures, communication errors, and unreliable readings.
|
||
|
||
**Opto-Coupler Relay Module:**
|
||
|
||
```text
|
||
Low Voltage Side (Pico):
|
||
GP15 (Pin 20) → IN (Signal)
|
||
3.3V (Pin 36) → VCC
|
||
GND → GND
|
||
|
||
High Voltage Side (AC Unit):
|
||
NO (Normally Open) → AC Control Wire 1
|
||
COM (Common) → AC Control Wire 2
|
||
```
|
||
|
||
**Note:** Most opto-coupler modules work with standard logic:
|
||
|
||
- `relay.on()` = relay energized (NO closes) = AC ON
|
||
- `relay.off()` = relay de-energized (NC closes) = AC OFF
|
||
|
||
If your AC behavior is inverted (turns on when it should be off), your module may be active LOW—see troubleshooting section.
|
||
|
||
**Optional Reset Button:**
|
||
|
||
```text
|
||
RUN pin → Button → GND
|
||
```
|
||
|
||
Pressing button grounds RUN and resets the Pico.
|
||
|
||
### 3. Software Setup
|
||
|
||
**Install MicroPython:**
|
||
|
||
1. Download [MicroPython firmware](https://micropython.org/download/rp2-pico-w/)
|
||
2. Hold BOOTSEL button while plugging in Pico
|
||
3. Copy `.uf2` file to the Pico drive
|
||
|
||
**IDE Setup:**
|
||
|
||
- Recommended: VS Code with [MicroPico extension](https://marketplace.visualstudio.com/items?itemName=paulober.pico-w-go) by paulober
|
||
- Alternative: Thonny IDE
|
||
|
||
### 4. Configuration
|
||
|
||
**Create `secrets.py`** (copy from `secrets.example.py`):
|
||
|
||
```python
|
||
secrets = {
|
||
'ssid': 'YOUR_WIFI_NAME',
|
||
'password': 'YOUR_WIFI_PASSWORD',
|
||
'discord_webhook_url': 'https://discord.com/api/webhooks/...',
|
||
'discord_alert_webhook_url': 'https://discord.com/api/webhooks/...',
|
||
}
|
||
```
|
||
|
||
**Configure sensors and AC in `main.py`:**
|
||
|
||
```python
|
||
# Sensor configuration
|
||
SENSOR_CONFIG = {
|
||
'inside': {
|
||
'pin': 10,
|
||
'label': 'Inside',
|
||
'alert_high': 80.0,
|
||
'alert_low': 70.0
|
||
},
|
||
'outside': {
|
||
'pin': 11,
|
||
'label': 'Outside',
|
||
'alert_high': 85.0,
|
||
'alert_low': 68.0
|
||
}
|
||
}
|
||
|
||
# AC Controller options
|
||
relay_pin = 15
|
||
min_run_time = 300 # Minimum 5 minutes run time
|
||
min_off_time = 180 # Minimum 3 minutes off time
|
||
|
||
# AC Monitor options
|
||
target_temp = 75.0 # Target temperature in °F
|
||
temp_swing = 2.0 # ±2°F swing (AC on at 77°F, off at 73°F)
|
||
```
|
||
|
||
### 5. Upload & Run
|
||
|
||
Upload all files to your Pico:
|
||
|
||
```text
|
||
/
|
||
├── main.py
|
||
├── secrets.py
|
||
└── scripts/
|
||
├── air_conditioning.py
|
||
├── discord_webhook.py
|
||
├── monitors.py
|
||
├── networking.py
|
||
└── temperature_sensor.py
|
||
```
|
||
|
||
The Pico will auto-start `main.py` on boot.
|
||
|
||
## Project Structure
|
||
|
||
```text
|
||
Auto-Garden/
|
||
├── main.py # Entry point, configuration, monitor setup
|
||
├── secrets.py # WiFi & Discord credentials (gitignored)
|
||
├── secrets.example.py # Template for secrets.py
|
||
└── scripts/
|
||
├── air_conditioning.py # AC controller with short-cycle protection
|
||
├── discord_webhook.py # Discord notification handling
|
||
├── monitors.py # Monitor base class & implementations
|
||
├── networking.py # WiFi connection management
|
||
└── temperature_sensor.py # DS18B20 sensor interface
|
||
```
|
||
|
||
## How It Works
|
||
|
||
### Temperature Monitoring
|
||
|
||
- **Every 10 seconds:** Check temperatures, send alerts if out of range
|
||
- **Every 30 seconds:** Regular temperature reports to Discord + log to file
|
||
|
||
**Discord Channels:**
|
||
|
||
- `discord_webhook_url`: Regular temperature updates, connection status
|
||
- `discord_alert_webhook_url`: Critical temperature alerts (Inside sensor only)
|
||
|
||
### AC Control Logic
|
||
|
||
- **Every 30 seconds:** Check inside temperature and decide AC state
|
||
- **Temperature swing:** Creates a "dead band" to prevent rapid cycling
|
||
- Example: Target 75°F with 2°F swing
|
||
- AC turns **ON** when temp > 77°F
|
||
- AC turns **OFF** when temp < 73°F
|
||
- Between 73-77°F: maintains current state
|
||
|
||
**Short-Cycle Protection:**
|
||
|
||
- Minimum run time (default 5 min) prevents AC from turning off too quickly
|
||
- Minimum off time (default 3 min) protects compressor from rapid restarts
|
||
|
||
### WiFi Monitoring
|
||
|
||
- **Every 5 seconds:** Check WiFi connection status
|
||
- **LED Indicator:**
|
||
- Slow blink (1 sec on/off): Connected
|
||
- Fast blink (0.2 sec): Disconnected
|
||
- **Auto-reconnect:** Attempts reconnection every 60 seconds if disconnected
|
||
|
||
## Temperature Logs
|
||
|
||
Logs are saved to `/temp_logs.csv` on the Pico:
|
||
|
||
```csv
|
||
2025-11-05 14:30:00,Inside,28000012,72.50
|
||
2025-11-05 14:30:00,Outside,28000034,45.30
|
||
```
|
||
|
||
Format: `timestamp,location,sensor_id,temperature_f`
|
||
|
||
## Customization
|
||
|
||
All configuration is centralized in `main.py`:
|
||
|
||
**Sensor Settings:**
|
||
|
||
- Pin assignments
|
||
- Alert thresholds (high/low)
|
||
- Labels
|
||
|
||
**AC Settings:**
|
||
|
||
- Relay pin
|
||
- Target temperature
|
||
- Temperature swing (dead band)
|
||
- Minimum run/off times
|
||
|
||
**Monitor Intervals:**
|
||
|
||
- Temperature check/report intervals
|
||
- WiFi check interval
|
||
- AC control interval
|
||
|
||
## Safety Notes
|
||
|
||
⚠️ **High Voltage Warning:**
|
||
|
||
- Opto-couplers isolate the Pico from AC voltage
|
||
- Never connect GPIO pins directly to 110V AC
|
||
- Ensure your opto-coupler module is rated for your voltage
|
||
- Test relay switching with a multimeter before connecting AC
|
||
- Consider hiring a licensed electrician if uncomfortable with AC wiring
|
||
|
||
**Compressor Protection:**
|
||
|
||
- Always use minimum run/off times (defaults are safe)
|
||
- Minimum 3 minutes off time protects compressor bearings
|
||
- Minimum 5 minutes run time prevents short cycling
|
||
|
||
## Future Expansion
|
||
|
||
### Planned Features
|
||
|
||
- **Humidity Sensors:** DHT22 or SHT31 for air humidity monitoring
|
||
- **Soil Moisture:** Capacitive sensors for plant watering automation
|
||
- **Additional Relays:** Control for fans, heaters, grow lights
|
||
- **Smart Ventilation:** Auto-open windows when outside air is optimal
|
||
- **Light Monitoring:** LDR or BH1750 for day/night cycles
|
||
|
||
### Adding More Sensors
|
||
|
||
To add a new temperature sensor:
|
||
|
||
First Add to `SENSOR_CONFIG` in `main.py`:
|
||
|
||
```python
|
||
'greenhouse': {
|
||
'pin': 12,
|
||
'label': 'Greenhouse',
|
||
'alert_high': 90.0,
|
||
'alert_low': 50.0
|
||
}
|
||
```
|
||
|
||
Second Add a `TemperatureMonitor` to the monitors list:
|
||
|
||
```python
|
||
TemperatureMonitor(
|
||
sensor=sensors['greenhouse'],
|
||
label=SENSOR_CONFIG['greenhouse']['label'],
|
||
check_interval=10,
|
||
report_interval=30,
|
||
alert_high=SENSOR_CONFIG['greenhouse']['alert_high'],
|
||
alert_low=SENSOR_CONFIG['greenhouse']['alert_low'],
|
||
log_file="/temp_logs.csv",
|
||
send_alerts_to_separate_channel=False
|
||
)
|
||
```
|
||
|
||
## Troubleshooting
|
||
|
||
**No temperature readings:**
|
||
|
||
- Check 4.7kΩ pull-up resistor is connected between data line and 3.3V
|
||
- Verify sensor wiring (VDD to 3.3V, not 5V)
|
||
- Check GPIO pin numbers in `SENSOR_CONFIG`
|
||
- Run `sensor.scan_sensors()` to detect connected sensors
|
||
|
||
**WiFi not connecting:**
|
||
|
||
- Verify SSID/password in `secrets.py`
|
||
- Check 2.4GHz WiFi (Pico W doesn't support 5GHz)
|
||
- Look for connection messages in serial console
|
||
- LED should blink slowly when connected
|
||
|
||
**Discord messages not sending:**
|
||
|
||
- Verify webhook URLs are correct
|
||
- Test webhooks with curl/Postman first
|
||
- Check Pico has internet access
|
||
|
||
**AC not switching:**
|
||
|
||
- Verify relay pin number (default GP15)
|
||
- Test relay manually: `Pin(15, Pin.OUT).off()` should activate it
|
||
- Check if module is active LOW or active HIGH
|
||
- Ensure opto-coupler has 3.3V power
|
||
- Look for LED on relay module (should light when active)
|
||
- Verify minimum run/off times haven't locked out switching
|
||
|
||
**AC behavior inverted:**
|
||
|
||
- Your opto-coupler is likely active LOW
|
||
- In `air_conditioning.py`, swap `relay.on()` and `relay.off()` calls
|
||
|
||
## Contributing
|
||
|
||
Feel free to open issues or submit pull requests for improvements!
|
||
|
||
## License
|
||
|
||
MIT License - See LICENSE file for details
|
||
|
||
## Resources
|
||
|
||
- [Raspberry Pi Pico W Documentation](https://www.raspberrypi.com/documentation/microcontrollers/raspberry-pi-pico.html)
|
||
- [MicroPython Documentation](https://docs.micropython.org/)
|
||
- [DS18B20 Datasheet](https://www.analog.com/media/en/technical-documentation/data-sheets/DS18B20.pdf)
|
||
- [Discord Webhooks Guide](https://discord.com/developers/docs/resources/webhook)
|
||
- [1-Wire Protocol Guide](https://www.analog.com/en/technical-articles/guide-to-1wire-communication.html)
|
||
|
||
---
|
||
|
||
**Note:** Always ensure proper electrical safety when working with high-voltage relays and AC power. Test thoroughly before leaving unattended.
|