diff --git a/Scripts/web_server.py b/Scripts/web_server.py index 9d98c35..59f23c5 100644 --- a/Scripts/web_server.py +++ b/Scripts/web_server.py @@ -123,6 +123,33 @@ class TempWebServer: print("DEBUG: Schedule editor page sent successfully ({} bytes total)".format(len(response_bytes))) return + elif 'GET /settings' in request: + response = self._get_settings_page(sensors, ac_monitor, heater_monitor) + response_bytes = response.encode('utf-8') + + conn.send('HTTP/1.1 200 OK\r\n') + conn.send('Content-Type: text/html; charset=utf-8\r\n') + conn.send('Content-Length: {}\r\n'.format(len(response_bytes))) + conn.send('Connection: close\r\n') + conn.send('\r\n') + + chunk_size = 1024 + for i in range(0, len(response_bytes), chunk_size): + chunk = response_bytes[i:i+chunk_size] + conn.send(chunk) + + conn.close() + print("DEBUG: Settings page sent successfully ({} bytes total)".format(len(response_bytes))) + return + + elif 'POST /settings' in request: + response = self._handle_settings_update(request, sensors, ac_monitor, heater_monitor, schedule_monitor, config) + if isinstance(response, str) and response.startswith('HTTP/1.1'): + conn.sendall(response.encode('utf-8')) + conn.close() + print("DEBUG: Settings update redirect sent") + return + elif 'POST /schedule' in request: response = self._handle_schedule_update(request, sensors, ac_monitor, heater_monitor, schedule_monitor, config) # Redirects are already complete HTTP responses, send directly @@ -505,19 +532,24 @@ class TempWebServer: for pair in body.split('&'): if '=' in pair: key, value = pair.split('=', 1) - params[key] = float(value) + # Don't convert hold_type to float + if key == 'hold_type': + params[key] = value + else: + params[key] = float(value) + + # Check which hold button was clicked + hold_type = params.get('hold_type', 'temp') # Default to temp hold + is_permanent = (hold_type == 'perm') # ===== START: Validate Heat <= AC ===== - # Get the values that will be set new_heater_target = params.get('heater_target', config.get('heater_target', 80.0)) new_ac_target = params.get('ac_target', config.get('ac_target', 77.0)) - # Validation: Heater must be <= AC if new_heater_target > new_ac_target: print("❌ Validation failed: Heater target ({}) cannot be greater than AC target ({})".format( new_heater_target, new_ac_target )) - # Return error page return self._get_error_page( "Invalid Settings", "Heater target ({:.1f}°F) cannot be greater than AC target ({:.1f}°F)".format( @@ -529,39 +561,35 @@ class TempWebServer: # ===== START: Update AC Settings ===== if 'ac_target' in params and ac_monitor: - ac_monitor.target_temp = params['ac_target'] # Update monitor - config['ac_target'] = params['ac_target'] # Update config + ac_monitor.target_temp = params['ac_target'] + config['ac_target'] = params['ac_target'] print("AC target updated to {}°F".format(params['ac_target'])) - - if 'ac_swing' in params and ac_monitor: - ac_monitor.temp_swing = params['ac_swing'] # Update monitor - config['ac_swing'] = params['ac_swing'] # Update config - print("AC swing updated to {}°F".format(params['ac_swing'])) # ===== END: Update AC Settings ===== # ===== START: Update Heater Settings ===== if 'heater_target' in params and heater_monitor: - heater_monitor.target_temp = params['heater_target'] # Update monitor - config['heater_target'] = params['heater_target'] # Update config + heater_monitor.target_temp = params['heater_target'] + config['heater_target'] = params['heater_target'] print("Heater target updated to {}°F".format(params['heater_target'])) - - if 'heater_swing' in params and heater_monitor: - heater_monitor.temp_swing = params['heater_swing'] # Update monitor - config['heater_swing'] = params['heater_swing'] # Update config - print("Heater swing updated to {}°F".format(params['heater_swing'])) # ===== END: Update Heater Settings ===== - # ===== START: ALWAYS enter temporary hold when Save Settings is clicked ===== - # User clicked "Save Settings" - enter temporary hold mode + # ===== START: Enter hold mode based on button clicked ===== config['schedule_enabled'] = False - config['permanent_hold'] = False - config['temp_hold_start_time'] = time.time() # SET START TIME - print("⏸️ Temporary hold activated - Manual override") + config['permanent_hold'] = is_permanent + + if is_permanent: + # Permanent hold - no timer + config['temp_hold_start_time'] = None + print("🛑 Permanent hold activated - Manual control") + else: + # Temporary hold - set timer + config['temp_hold_start_time'] = time.time() + print("⏸️ Temporary hold activated - Manual override (1 hour)") # Reload schedule monitor to disable it if schedule_monitor: schedule_monitor.reload_config(config) - # ===== END: ALWAYS enter temporary hold ===== + # ===== END: Enter hold mode ===== # ===== START: Save settings to file ===== @@ -572,7 +600,6 @@ class TempWebServer: try: with open('config.json', 'r') as f: updated_config = json.load(f) - # Update the passed-in config dict (updates reference, not copy) config.clear() config.update(updated_config) print("✅ Config reloaded into memory") @@ -584,29 +611,21 @@ class TempWebServer: # ===== START: Send Discord notification ===== try: from scripts.discord_webhook import send_discord_message - ac_target_str = str(params.get('ac_target', 'N/A')) - ac_swing_str = str(params.get('ac_swing', 'N/A')) - heater_target_str = str(params.get('heater_target', 'N/A')) - heater_swing_str = str(params.get('heater_swing', 'N/A')) + hold_label = "PERMANENT HOLD" if is_permanent else "TEMPORARY HOLD" + duration = "" if is_permanent else " (1 hour)" - message = "⏸️ TEMPORARY HOLD - AC: {}F ± {}F | Heater: {}F ± {}F (1 hour)".format( - ac_target_str, ac_swing_str, heater_target_str, heater_swing_str + message = "{} {} - AC: {}°F | Heater: {}°F{}".format( + "🛑" if is_permanent else "⏸️", + hold_label, + params.get('ac_target', 'N/A'), + params.get('heater_target', 'N/A'), + duration ) send_discord_message(message) except Exception as discord_error: print("Discord notification failed: {}".format(discord_error)) # ===== END: Send Discord notification ===== - # ===== START: Debug output ===== - print("DEBUG: After update, monitor values are:") - if ac_monitor: - print(" AC target: {}".format(ac_monitor.target_temp)) - print(" AC swing: {}".format(ac_monitor.temp_swing)) - if heater_monitor: - print(" Heater target: {}".format(heater_monitor.target_temp)) - print(" Heater swing: {}".format(heater_monitor.temp_swing)) - # ===== END: Debug output ===== - except Exception as e: print("Error updating settings: {}".format(e)) import sys @@ -1012,8 +1031,8 @@ class TempWebServer: -
- """ \ No newline at end of file + """ + + def _get_settings_page(self, sensors, ac_monitor, heater_monitor): + """Generate advanced settings page.""" + config = self._load_config() + + # Get temperatures (read if not cached) + inside_temp = getattr(sensors.get('inside'), 'last_temp', None) + if inside_temp is None: + inside_temps = sensors['inside'].read_all_temps(unit='F') + inside_temp = list(inside_temps.values())[0] if inside_temps else "N/A" + + outside_temp = getattr(sensors.get('outside'), 'last_temp', None) + if outside_temp is None: + outside_temps = sensors['outside'].read_all_temps(unit='F') + outside_temp = list(outside_temps.values())[0] if outside_temps else "N/A" + + inside_temp_str = "{:.1f}".format(inside_temp) if isinstance(inside_temp, float) else str(inside_temp) + outside_temp_str = "{:.1f}".format(outside_temp) if isinstance(outside_temp, float) else str(outside_temp) + + html = """ + + + +